fcu screwfix. 5mm2 to 5amp fused switch >>> 1. fcu screwfix

 
5mm2 to 5amp fused switch >>> 1fcu screwfix  Over 40,000 products

In my opinion it's no different to using 2. It may work perfectly fine at the moment, but personally I would not do it. FREE next day delivery available, free collection in 1 minute. All loans subject to credit approval. 4. Masterseal IP56 13A Sw FCU, at Screwfix Direct Masterseal range has been specifically designed for use either outdoors or indoors and in areas heavily exposed to dust and splashing water. I'm building some large pantry style cupboards in the space below and wondered if there was any reason using a FCU where the switch used to be to power some LED lights in the cupboard would be a bad. Raised Slim Profile. The easiest way I can see to do this (without extending the boiler load cable, making additional hole and moving the FCU due to cable length) is to run an additional cable from the supply side of the FCU to the socket above through the. Without RCD. screwguy, Mar 31, 2005. Requires 35mm Back Box. With RCD. This, according to the regs, is not allowed. Add To Cart. I have inserted an fcu in to my kitchen ring. The coax aerial cable from the TV is then looped in to the transformer and out again to the aerial coax socket. Simply screw to tighten or loosen grip of pipe. Below is just a tiny selection of what you'll find at Screwfix Online:fitting a 4pole 32A rotary isolation switch to act as an isolator in a twin and earth wiring single phase 16A circuit leading to an invertor. £ 1. RolandK Screwfix Select I want to add some sockets on a spur from the existing ring final. KC DIY, Jun 24, 2021. 60 days free credit available. com. British General 900 Series 13A Unswitched Passive Fused Spur White (8250P) (57) compare. com. Isolate power at your consumer unit/fusebox using the main switch. There is no rule saying you cannot take 2 spurs from the same point on a ring. 0mm cable you have fulfilled all the requirements of the regulations as long as it is okay for volt drop and you have used water-proof glands (CW type). Bazza, Aug 30, 2020 #9. for the cooker hood. Area manager for the bathroom company argued the toss about a FCU in zone 3 so i wanted all you good people to confirm my interpretation. Ind spark, Sep 15, 2023. Transfer funds between your accounts. 5 and the regs allow for a smaller conductor and cpc size. Ho hum such is the way of things. load. 9. There is very little wall space to chase out more space for extra switches. Added protection against electric shock. Pay your way. Wood Products. Once you are logged in, click or tap the 'More' tab in the bottom navigation menu. Home Forums > Screwfix Community Forum > Electricians' Talk > 2 core flex from fcu. Free returns. Buy online & collect in hundreds of stores in as little as 1 minute! Pay your way. com. Without RCD. can you leave it in or out depending on cabling within the box. In Wales the garden is still a special location, so may still need notifying. Screwfix customers rate this product 4. HandyAndy - really Mr. £ 13. Can I put this single plate device in place of my existing single gang socket, and replace this existing socket as part of the new spur?. CraigMcK Screwfix Select. J804 which will give you the capability for the switched live too, meaning from teh junction box a T&E pair to teh switch and T&E to the lights. 666. Requires 25mm Back Box. CCX Plywood, 3/4 in x 4 ft x 8 ft - Southern Pine, Pressure Treated. 75, 1 or 1. Buy MK FCU Switches & Sockets at Screwfix. Screwed Faceplate. FlyByNight Screwfix Select. At the Screwfix online store you'll find all manner of DIY products, discounts and best-ever prices. Just a point though when you install the FCU ensure you fit the correct size fuse for the cable, sounds like 0. com. So I want to protect the existing socket with a Power Breaker RCD Fused Spur, as sold by Screwfix. The maximum amperage would be 13 amps as your using a fcu it would be pointless going any bigger or smaller. Products reviewed by the trade and home improvers. Joe Public don't understand very much at all about their electrical installation. Coloumb Screwfix Select. Delivered by our approved supplier, Find out more. High Protection from Water & Dust. 14th 14th edition, Jan 19, 2007 #2. Transfer between multiple deposit accounts & pay loans. Away from the first or last 20% of the ends it is impossible to overload a leg as has been demonstrated. Buy online & collect in hundreds of stores in as little as 1 minute! Thousands of customer product reviews. #4. If you want to protect the fan wiring with a 3A FCU or whatever, you could put a cheaper 2 pole FCU on the live/neutral feed to the lighting, saves the expensive of having a 3 pole switch just for the fan. Type the amount you will pay and when you want the payment to post. I’m not sure anything exists. Optional flex outlet at the base of the front plate provides additional space for larger cables. Hi all, I've installed an LED floodlight vertically above an FCU switch, and used some 25mm conduit and fittings that I already had. terrymac, Oct 6, 2019. Dunno Squash - prefer a plug and socket in that scenario, but hey ho manufacturers instructions and all. 5mm², 2 x 4mm² or 1 x 6mm² cables. To switch this on or off you switch the switch. Buy FCU Fused Spurs at Screwfix. See pic for context. Requires 35mm Back Box. However, saw several FCU's this week all on a ring next to each other then used for towel rails, UF heating etc. Just wondering why no-one makes a 2gang ccu with a switched FCU, rather than with a 13A socket. Flex Outlet. #7. An FCU is not switchgear. Field Offices handle scheduled interviews on other applications. FCU: Switches & Sockets Profile Type: Raised Rounded: Terminal Capacity: Terminals accept 3 x 2. 60 days free credit available. They are available in a variety of current ratings (eg 16A, 32, etc). 40m/sec Trip Speed. That FCU will then be connected to the TV socket and another socket for the virgin box. com. You can take one double or one single socket on one spur. spirits are real 2016 Screwfix Select. The whole set up from the consumer unit could be a radiel circuit or the spur could be taken from a junction box thats why theres only two cables at each socket. There is no rule saying you can’t take two spurs from one point on the ring. . Discussion in ' Electricians' Talk ' started by DoItYoung, Feb 9, 2021 . The issue begins because the appliance does not come with a plug or cable fitted. Screwless Faceplate. Apple Pay accepted in store. spirits are real 2016 Screwfix Select. ”. Raised Rounded Profile. Home Forums > Screwfix Community Forum > Electricians' Talk > Replacing 13 amp double socket with 2 FCU's. Buy Unswitched FCU Switches & Sockets at Screwfix. 5/5. com. Titan TTB776VAC 1400W 30Ltr Wet & Dry Vacuum 220-240V (665KH) (101) compare. Anyway ,rather than fit a light switch in the kitchen ,which you can do if you wish ,fitting a switched fcu would make the wiring simpler. 0mm cables, therefore 2 x 2. Screwfix customers rate this product 4. For example, with Screwfix Direct Catalogue, you can buy all kinds of high quality building materials, and maintenance and refurbishment items. So my plan was to add a fused spur to a ring main, run. . 5mm² cables. The 1. Screwfix Community Forum. Terminal Capacity. I know 1 metre sounds a small amount but just want to do it properly and so it lasts. Wood. Marine Credit UnionEnroll in Digital Banking. 1. Buy FCU Fused Spurs at Screwfix. FREE next day delivery available, free collection in 1 minute. Call us at 512. Online Banking Features. Can I do any of the following and maintain compliance with the regs? My preferred plan: Connect in an external IP54+ 3A FCU via the (feed or switch?) @ 13A FCU with appropriate cable (1. Pearwood effect. 00% min$500 12-month Liquid CD stayed at 5. Bazza, Aug 30, 2020 #9. Step 2 isolates the entire outside. Home Forums > Screwfix Community Forum > Electricians' Talk > FCU on 1. There is a rule saying one spur can only have a single or double socket or FCU though. Discussion in ' Electricians' Talk ' started by DoItYoung, Feb 9, 2021 . com. This is to feed the extractor fan. Thousands of customer product reviews. Terminal Capacity. MK FCU Switches & Sockets (17 products) Categories Fused Spurs (17) Filters (1 applied) Clear all Brand British General (27) Crabtree (26) Essentials (4) LAP (33) MK (17). Products reviewed by the trade and home improvers. Add the account you wish to pay from. Regards isolation they tell me it’s fine because the kitchen sockets are on an independent circuit on the new MCB so isolated there. Our advanced system is protected by state-of-the-art security and includes all the latest conveniences in online banking. Delivery 7 days a week Choose from top trade brands. If you wish to take more sockets, then you spur first to a fused connection unit (FCU) then on to the further sockets, you can have as many as you like down stream of the FCU but of course. 13A Switched Fused Connection Unit Spur White (2323D)Extend the ring by joining one of the legs in the back of the box, run this to the supply side of first fcu, supply side of second fcu and then back and terminate in the socket keeping the ring intact. Buy 45 A Fused Spurs at Screwfix. Either tap off a nearby socket outside the bathroom on to an fcu or run a wire down from the loft off the lighting circuit to a switched fcu. . Screwfix Community Forum. Set Up Account Alerts Today – here’s how it works: 1. Therefore I am proposing: 2. PayPal accepted online. Contact PenFed by Phone. Delivery 7 days a week The UK’s leading retailer of trade tools and hardware. Angled In-Line Terminals with Backed-Out Captive Screws. From the settings menu, click or tap on 'Push Notifications'. Let us help you with a pre-approved auto loan to ensure you know how much you can afford before you buy. The FCU is spurred off from a Double Socket which is earthed. I also think it looks like part of a RCD, it may connect to the moulded breaker, I remember us having a lot of them in weather proof distribution units, but seem to remember they has a small unit between the two where you can set time delay and leakage current, went up to 1 minute and 5 amp. After looking at the switch wiring, it looks like it is a double pole switch with a load and supply. Find your nearest Screwfix store and up to date opening times. 3. However, from a practical point of view you would change the present fcu to an unswitched 13A spur, then connect two 3A fcus one serving each of the boiler and the pump. Discussion in 'Electricians' Talk' started by seneca2, Nov 27, 2007. The circuit shall be wired with copper conductors having line and neutral. Volex 13A Sw DP FCU - Screwfix. Bazza-spark, Sep 15, 2023. The whole set up from the consumer unit could be a radiel circuit or the spur could be taken from a junction box thats why theres only two cables at each socket. 036 cable. 89Inc Vat. With online banking services from AERO Federal Credit Union, it’s never been easier—or safer—to manage your money online. Change the single box to a dual 35mm box. Pay your way. 5 or 2 x 4. Need Help. My entire bathroom (5 spots, power for mirror and extractor fan) are done this way, single DP FCU with 3A fuse serving the lot. com. Evening all, I have an old airing cupboard above the kitchen with an immersion heater radial in it that is no longer used as we have a combi. Log in to Online Banking on your mobile device. I want to disconnect the existing wiring from the old CU and. Sign in / Register. PayPal accepted online. Order online at Screwfix. PayPal accepted online. In which case the "fused spur," the fused flex, the fused cable, the fused load, whatever you call it, is functionally part of the accessory. So the switched FCU will have a spur off the feed side That OK Switches will be labledunphased Screwfix Select For the short lengths involved just use 2. Once inside the shed put the swa inside a junction box and connect it to two 2. Order MK Metal-Clad Plus 13A Switched Metal Clad Fused Spur & Flex Outlet with White Inserts at Screwfix. Hans_25 said: ↑. as it's already a spur the socket should be fed through the fcu as well but the problem there would be that as the cooker hood probably only requires a 3 amp fuse you wouldn't be able to draw much. Free next day delivery available. The red cable is attached to a twin brass connector block with the brown cable from the pendant light. 89Inc Vat. 5mm², 2 x 4mm² or 1. Home Forums > Screwfix Community Forum > Electricians' Talk > FCU for lights but not sockets on spur? Discussion in 'Electricians' Talk' started by Mr. The electrics have been set up as follows… Existing double socket (on ring circuit) ————- spurred double socket ——— FCU 13A——— double socket ——— double socket——- double socket. . To die?to sleep, No more; and by a sleep to say we end The heart-ache and the thousand remarks That flesh is heir to: 'tis a consummationHome Forums > Screwfix Community Forum > Electricians' Talk > Boiler and controller fcu Discussion in ' Electricians' Talk ' started by mrppp , Oct 11, 2016 . The UK’s leading retailer of trade tools and hardware. Feed the spur cable into the FCU mounting box, pull enough cable through to connect it to the face-plate. Wellwisher said: ↑. Many. I see,you mean article 48234. Screwfix Select Use a DA box and pay particular attention to the segregation plate. Delivery. Buy Switched FCU Switches & Sockets at Screwfix. this is a rcd fcu that in screwfix website shop, this is the unit i need yes. Flex Outlet. Screwfix customers rate this product 4. Supplied with Replaceable 13A Fuse. 5mm I'm guessing at 3a) to do so. Free next day delivery available. Coloumb Screwfix Select. Modern and intuitive design. Rounded switched fused connection unit. Deleted member 11267, Apr 23, 2018. Hi unphased, Yes it is in a cupboard next to the bath (within 600mm), with a door which can be opened easily (without the use of a tool/lock). #1. Its called remote power. #12. $5000. 5 mm. Buy FCU Fused Spurs at Screwfix. You need sufficient backbox space for 2x 2. . Many. Flex Outlet FCU Fused Spurs Profile Type Switched or Unswitched Price (Inc VAT) Sort By: Results per page: 20 MK Logic Plus 13A Switched Fused Spur & Flex Outlet White. 5 or 2. My old oven went wrong and I bought a new one. Hi, We have a couple of white appliances such as a dishwasher and tumble drier that have switched FCUs on the countertop and an unswitched socket below for the plug. 5mm² cables. Discussion in 'Electricians' Talk' started by Jim, Oct 7, 2004. Can you interrupt your ring main in a sensible place for the FCU to go?A spur off a ring can have one socket (single or double) or one FCU. Apple Pay accepted in store. 25Ltr Dry Capacity. This is perfectly OK, according to the regs. Yes of course there is. PayPal accepted online. Coloumb Screwfix Select. This little piece of 1. The supplied switch (from Screwfix) doesn't have a wiring diagram. uPVC Construction. Can't see any issue with having an FCU as part of the ring - the ones in the kitchen for fridge, washer etc are wired that way for example. Raised Rounded. But 2 is never a problem. Run the standard flex in to a standard flex outlet plate which will have a connector block inside it and then run some 1. com. Tbh what you plan there is do-able but it's a bit of a weird way of doing it. Assemble with other products into a modular front plate to create a grid. Actually they are all correctly called fused connection units (FCUs). Flex Outlet. 5mm cables via wago connectors. Order MK IP66 13A Weatherproof Outdoor Switched Fused Spur &. Membership is open to the family of existing. FREE next day delivery available, free collection in 1 minute. FREE next day delivery available, free collection in 1 minute. However if there is spurred socket, and then from that spurred socket another leg is run for the FCU, then this could be construed as a noo noo (although it is limited by the max 13 Amp fuse) With regards to adding it to the main, neither of the lights in the rooms adjacent to the conservatory have loop-in pendants. Delivery 7 days a weekOrder online at Screwfix. com. You still haven't answered the queston of how many spurs you think is acceptable from a single point. Spur/FCU. Pay your way. old menace, Jul 23, 2008. Free returns. 1/5. com. The plug must be outside the zones, which usually means 3 mts away from the bath or shower, unless the cupboard is locked or requires a tool to open it. Without RCD. Click & Collect. Don't know why there is a switch on the incoming feed, it is not necessary. com. Order online at Screwfix. Flex going through a correctly sized hole in the wall looks much neater than a flex outlet plate. Again check no power to alarm panel. Requires 35mm Back Box. com. FREE next day delivery available, free collection in 1 minute. Electrican has done the following, but isn't. 49 Inc Vat. spirits are real 2016, Feb 24, 2021. Requires 35mm Back Box. 60 days free credit available. I am electrical maintenance engineer, but have not done domestic work for a while. 2. 2x 2. 75% min$500 12-17 month 5. Temperature Range. Buy Screwed FCU Switches & Sockets at Screwfix. Spur off socket to unswitched FCU From unswitched FCU to a switched FCU (needed for functional switching of fly zapper) The load side of SFCU going to the fly zapper and from feed side of SFCU to another SFCU to power outside light. Me as well, FCU,& feed running up to a 1G unswitched socket. Terminals accept 3 x 2. ? this is the kudox box ip44 rated, again in screwfix website shop. 60 days free credit available. but having a FCU on a spur can cause problems, my dad decided to have a few sockets on a spur, and used a FCU. Can’t advise properly unless you can be more specific. Supplied with screwcaps and 2 x earth terminals for ease of looping. It probably is a 3Kw boiler with a 'carp' plug or socket. Thread by: itisgeorge , Mar 16, 2022 ,. 5 mm, providing it`s feeding a small load, the 1. FREE next day delivery available, free collection in 1 minute. Order 13A Switched Fused Spur with Neon White at Screwfix. Tiling round FCU's is no different to tiling round sockets above the worktop though. A spur is to do with whether it is spurred off the wiring. 1. Log in or Sign up. 5 from the load side of this spur with a 13 amp fuse into the supply side of a spur in the right hand side of the box. It was established in 1935 as Shell Employees Federal Credit Union, and now serves more than 30,000 members with more than $524 million in assets. Dare say your already aware but by using an FCU you'd be restricted to a total load of 13a across the two double sockets. £ 5. Information and resources to make well-informed financial decisions. May be better if you got an electrician to advise. 99Inc Vat. Without Flex Outlet. Skip to content. The FCU is in the middle of the garage (as is the original garage socket it is spurring off) and my new socket powering the LED deck lights is at one end. FREE next day delivery available, free collection in 1 minute. Just wanted to check. Thread Lighting Spur off mains. wally, Nov 28, 2007 #81. 25 gallon Tank with lid. Area of bathroom is 2. 84 Inc Vat. dabhand New Member. acca Guest. 5mm t&e from this. Delivery 7 days a weekShaver sockets are allowed in zones 2 + 3 in bathrooms (601-08-01) Yup - proper shaver sockets with an isolation transformer are. PAGE 1 OF 3. Captive Terminal Screws. Buy Fixings & Fastenings at Screwfix. com. Last Day: Grab DeWalt safety boots and clothing with 10% off at Screwfix. 5mm swa. Hi guys got 3 klima 5m 750 watt heating Matt's in a kitchen. #9. That's two cables on the 'load' side of the FCU. I currently have an FCU supplying ONE outside PIR security light. Delivery 7 days a week. A 6A MCB protecting the lighting circuit will trip a long time before a 5A fuse can blow. Terminal Capacity. The extractor fan does not have and require a earth wire. Switched fused connection unit 13A double pole. Learn More. With RCD. Apple Pay accepted in store. It will enter the FCU at the bottom. Download account information into Quicken. Raised Rounded. 5mm², 2 x 4mm² or 1 x 6mm² cables. Bob Rathbone Screwfix Select. Order LAP 13A Switched Fused Spur Brushed Stainless Steel with White Inserts at Screwfix. Raised Square. Home Forums > Screwfix Community Forum > Electricians' Talk > FCU of ring for light. 30 day money back guarantee. Bob Rathbone said: ↑. Lectrician Screwfix Select. The essence is that you can actually overload the connection point. FREE next day delivery available, free collection in 1 minute. 5mm², 2 x 4mm² or 1 x 6mm² cables. An electrician would be forced to have to hard wire it, run a 6mm2 cable from the consumer unit on a 32Amp RCD protected circuit specifically dedicated into a cooker FCU. FlyByNight Screwfix Select. Choose from top trade brands. Buy FCU Fused Spurs at Screwfix. Worth mentioning that I've drilled a drain hole in the FCU. Screwed Faceplate.